The PowerLINE® generator set contains a 23.9 KW V2203-DI* engine and a 15 kW wound generator. The engine includes an electronic governor system that provides near-constant engine speed, which results in more stable voltage output.

The powerful, reliable; low- maintenance field wound generator produces 460 volts of continuous power and features an internally excited, self-regulated design. All electrical components are enclosed within the generator package and provide superior resistance to moisture and salt.

 

Buy Carrier Clip On Genset 69RG15 Online

Carrier Clip On Genset 69RG15 For Sale

Buy Carrier Genset 69RG15 Online

 

PowerLINE RG15 Tier 4 Interim

POWER YOU’LL GET SIMPLY ATTACHED TO.

Buy Carrier Clip On Genset 69RG15

  • Industry-leading PowerLINE generator sets from Carrier Transicold are designed and built for one purpose: continuous, unattended operation for all refrigerated containers transported by road or rail. PowerLINE generator sets offer the ideal combination of horsepower, torque, and motor-starting capability and provide power to start any ISO reefer, anywhere it’s necessary.
  • Whether you choose clip (RG15) or undermount (UG15), PowerLINE generator sets provide more mounting flexibility. Attaching and disconnecting the generator set can take just minutes.
    • For clip-on mounting, the RG15 pin-mounting bracket design saves time; for clamp mounting, the self-aligning ratcheted clamp locks allow safe, secure attachment to corner castings.
    • For undermount, you can choose standard four-point mounting or our exclusive QuickMount™ design available on the UG15 generator set.

 

  • Outstanding convenience and safety make the PowerLINE generator set number one for operating control. Up-front analog instrumentation is easy to read and allows immediate access to key operating parameters. The control system is uncomplicated, easy to access and troubleshoot.
  • The Tier 4 interim PowerLINE generator set is built with an export engine, belongs in the 19-37 KW class and meets emission levels specified by the US EPA Tier 4 interim emission standard. The units built with these export engines are exclusively for sale/use outside the United States.*

RUGGED CONSTRUCTION, DEPENDABLE POWER, SIMPLE OPERATION.

Carrier Clip On Genset 69RG15

The PowerLINE® generator set contains a 23.9 KW V2203-DI* engine and a 15 kW wound generator. The engine includes an electronic governor system that provides near-constant engine speed, which results in more stable voltage output. The powerful, reliable; low- maintenance field wound generator produces 460 volts of continuous power and features an internally excited, self-regulated design. All electrical components are enclosed within the generator package and provide superior resistance to moisture and salt.

Gensets (Clip On) - RAVA Group Container Services

The model 69RG15 mounts to properly equipped ISO containers, in front of the refrigeration unit’s upper face. Generator sets are typically provided with “pin” mounting to attach to the container’s header rail. Clamp mounting to the corner casting of the container is available as an option.

 

In either case, when mounted, the 69RG15 envelope allows access to the refrigeration unit control box. This applies to all Carrier and most competitive units as well. Additionally the design of the equipment considered a deep footprint to avoid tipping due to rough handling by yard forklifts, and fork pockets are extended and reinforced to eliminate fork tine damage.

The FuelWise™ option is available and can reduce fuel consumption up to 28%. This directly translates to a reduction of the unit’s carbon footprint by up to 28%.

POWERLINE RG15 TIER 4 WITH THE NEW POWERLINE® GENERATOR SETS, TIER 4 COMPLIANCE IS SURPRISINGLY SIMPLE WHILE FUEL SAVINGS ARE A BIG BENEFIT.Carrier’s newest PowerLINE generator sets deliver improved performance while achieving compliance with the 2013 Tier 4 emissions standard from the U.S. Environmental Protection Agency (EPA).

 

This upgraded line of PowerLINE generator sets incorporate ecoFORWARD™ technologies, resulting in a platform that is Carrier’s most fuel-efficient models to date, thanks to standard inclusion of the formerly optional FuelWise™ technology and use of a new ultra-high-efficiency 15 kW custom-designed permanent magnet generator. Fuel savings of up to 34% versus prior standard units provide customer with significant operational cost savings and longer hauls prior to refueling.

 

The enhanced PowerLINE units provide uninterrupted power to operate ISO container refrigeration systems when used over land in intermodal applications. At the heart of the new platform is the ultra-high efficiency permanent magnet generator that allows the power drawn from the engine to be reduced by 20%. Common to this new Tier 4 PowerLINE platform is the familiar 2.2-liter diesel engine now rated at 18.5 kW.

 

This engine is based on Carrier’s current engine line, with its well-accepted speed sensor and electronic governor. Providing customers with a familiar, reliable engine means that their personnel do not have to learn operate and deal with complex new engine technology in the field while reaping the operational benefits of our high efficiency compliance platform.

 

The PowerLINE Tier 4 platform is compliant with U.S. EPA Tier4. It is also compliant with California Air Resources Board (CARB) standards upon purchase and for seven years thereafter without further modification. After seven years, CARB requires further emissions reductions for the engine class (8-19 kW) for units operating in California.

In response, Carrier developed an optional engine emissions system (EES)* for the Tier 4 PowerLINE models, designed to achieve compliance with CARB’s ultra-low diesel emissions standard known as ULETRU. Tier 4 PowerLINE units will need to be fitted with the EES option by the end of the seventh year, if they are to remain in use in California. The option would be available as either a factory or field install option.

 

T-272 Rev F Change 12/06
Carrier Transicold
Diesel Driven Generator Set
Operation & Service
Model 69RG15

APPRECIATE THESE ADDITIONAL SYSTEM ADVANCEMENTS.
  • Simple, easy-to-operate, reliable.
  • V2203-DI 4-cylinder, water-cooled, 2.2-liter direct-injection 32 HP/23.9 KW diesel engine which meets EPA Tier 4 interim standard (unit only for export outside the US).*
  • Nominal 15 kW brushless, self-regulated generator, 460V output.
  • 130-gallon (492-liter) fuel tank built into all-steel frame.
  • Pin mount system with clamp provision (Clamp option). For easy attachment and detachment from container box.
  • Frame and sheet metal components powder-coated for durability and superior corrosion protection.
  • Carrier full-flow spin-on oil filter with internal bypass filtration is standard in all units and extends service intervals.
  • Integral fuel filter with water separator.
  • Fuel heater/Fuel warmer.
  • External In-line fuel strainer with clear bowl strains larger particles in fuel prior to entering the lift pump. The clear bowl allows visual inspection of the screen for clogging.
  • High-efficiency air cleaner (standard dry element, optional oil bath). Dry element, “cartridge”-style air filter with filter-minder allows for quick visual check of filter condition and signals when cartridge must be replaced.
  • Self-tensioning, flexible, Poly V belt eliminates the need for an idler pulley and the guesswork associated with manual tensioning. Optimum tension provided by the belt helps assure maximum life of the water pump bearing.
  • Stainless steel exhaust.
  • Patented E-coat tube and fin radiator.
  • 12V DC maintenance-free battery and solid state battery charger.
  • Safety stop controls for low oil pressure, high water temperature.
  • Large oil pan capacity extends running hours between oil changes.
  • Large aluminum service access door with self-locking/quick-release latch.
  • Stainless steel hardware.
  • Forklift pockets, extended and reinforced to eliminate fork tine damage.
  • FuelWise™ Option provides savings up to 28% versus single speed units.

 

Diesel Generator Set
OPERATIONS AND SERVICE
For 69RG15
Generator Set Units
Tier 4 – RG2051 to RG2100 Series

Buy Carrier Clip On Genset 69RG15

Ambient temperature range:
1. Structure                      -40 to +52°C    (-40 to +125°F)
2. Operation  – Start        -26 to +52°C    (-15 to +125°F)
2. Operation  – Run         -40 to +52°C    (-40 to +125°F)

Functionality – The RG provides a full 15kW output to power ISO reefer containers.

Approximate Weight:
830 kg (1,830 lb.), less fuel

Brochure
  • 62-10813, PowerLINE® Tier 4i – An alternative where EPA Tier 4i emissions levels meet or exceed local country standards. Published Date: 10/22/2019
Catalog
  • 62-03213, Performance Parts Service Tool Catalog Published Date: 1/4/2023
Newsletter
  • How FuelWise Works Published Date: 2/18/2021
  • More Choices, More Fuel Savings With PowerLINE Generator Sets Published Date: 2/18/2021
  • PowerLINE Generator Sets Do More Using Less in 2013 Published Date: 5/16/2019
  • U.S. EPA Tier 4 Requirements Bring Changes for Generator Sets Published Date: 5/16/2019
Operation
  • T-272, Diesel Generator Set. Model 69RG15, Prior to PID RG1135 Published Date: 3/4/2021
  • T-272S, Grupo generador a diesel. Modelo 69RG15 (Spanish) Published Date: 3/4/2021
  • T-339, Diesel Generator Set. Model 69RG15, PID RG1135 & Higher Published Date: 3/4/2021
  • T-345, Diesel Generator Set. Model 69RG15, PID RG1402 & Higher Published Date: 3/4/2021
  • T-345S, Unidad de Generador Diesel. Modelo 69RG15, Numero de identificacion de piezas PID RG1402 y superior (Spanish) Published Date: 3/4/2021
Parts
  • 62-03459, Diesel Engine Service Parts List. Models CT4-114/133/134 Prior to Serial Number XA0001 Published Date: 5/16/2019
  • 62-10295, Diesel Engine Service Parts List. Models CT4-134-DI Diesel Engine Serial Numbers XA0001 through 3Y0014 Published Date: 5/16/2019
  • 62-10863, Diesel Engine Service Parts List. Models V2203-DI (26-00119) Starting With Serial Numbers 3Y0015 Published Date: 5/16/2019
  • 62-11023, Service Parts List for Common Unitary Electrical Connectors and Components Published Date: 2/18/2021
  • 62-11335, Diesel Engine Service Parts List. Models V2203-DI (26-00128) Tier4i Published Date: 8/12/2020
  • 62-61732, Refrigeration Connection Components Spare Parts Manual Published Date: 2/18/2021
  • T-272PL, Diesel Generator Set. Service Parts List. Models 69RG15, Prior to PID RG1135 Published Date: 8/28/2023
  • T-339PL, Diesel Generator Set. Service Parts List. Models 69RG15, PID RG1135 & Higher Published Date: 8/28/2023
  • T-345PL, Diesel Generator Set. Service Parts List. Models 69RG15, PID RG1402 & Higher Published Date: 8/29/2023
Service
  • 62-11362, Diesel Engine Workshop Manual for V2203-DI (26-00128) Tier 4i Published Date: 8/12/2020
Technical Supplement
  • 62-10411, Diesel Driven Generator Set. Auto Restart Options for 69RG15 and UG15 Published Date: 5/16/2019
Warranty
  • 62-02489, Warranty Administration Policy and Procedures for Container Products Equipment Published Date: 1/25/2023
  • 62-03212, Flat Rate Warranty Labor Schedule Container Products Equipment Published Date: 8/31/2022

 

SAFETY SUMMARY

GENERAL SAFETY NOTICES
The following general safety notices supplement the specific warnings and cautions appearing elsewhere in this
manual. They are recommended precautions that must be understood and applied during operation and maintenance
of the equipment covered herein. The general safety notices are presented in the following three sections labeled:
First Aid, Operating Precautions and Maintenance Precautions. A listing of the specific warnings and cautions
appearing elsewhere in the manual follows the general safety notices.

FIRST AID
An injury, no matter how slight, should never go unattended. Always obtain first aid or medical attention immediately.

 

OPERATING PRECAUTIONS
Always wear safety glasses and hearing protection.
Keep hands, clothing and tools clear of the radiator fan and rotating belts.
No work should be performed on the unit until all circuit breakers and start-stop switches are turned off and the
negative battery terminal has been disconnected..
Always work in pairs. Never work on the equipment alone.
In case of severe vibration or unusual noise, stop the unit and investigate.

 

MAINTENANCE PRECAUTIONS
Be sure power is turned off and the negative battery cable is disconnected before working on generator set.
Do not bypass any electrical safety devices, e.g. bridging an overload, or using any sort of jumper wires. Problems with
the system should be diagnosed, and any necessary repairs performed, by qualified service personnel.
In case of electrical fire, open circuit switch and extinguish with CO 2 (never use water).
Fuel tanks present explosion, fire and rupture hazards even if liquid fuel has been drained. Do not attempt any repairs,
expecially repairs using flame, welder or torch, unless you have been properly trained and the tank has been emptied
of liquid fuel and fuel vapors and the tank is properly ventilated.

 

UNIT LABEL IDENTIFICATION
To help identify the hazard labels on the Unit and explain the level of awareness each one carries, explanations with
appropriate consequences are provided below:
DANGER — indicates an immediate hazard which WILL result in severe personal injury or death.
WARNING — indicates hazards or unsafe conditions which COULD result in severe personal injury or death.
CAUTION –indicates potential hazards or unsafe practices which COULD result in minor personal injury, product or
property damage.

SPECIFIC WARNING AND CAUTION STATEMENTS
The statements that follow are applicable to the generator set and appear elsewhere in this manual. These recom-
mended precautions must be understood and applied during operation and maintenance of the equipment covered
herein.

WARNING
To prevent injury, the procedures provided for installation and removal of the generator set must be
followed carefully.
WARNING
Disconnect power plug before removing generator set.
WARNING
Double-check that the generator set clamp (B) is securely tightened against the face of the corner
casting and that the generator set clamp hand nut is tight before transporting the container. A loose
fit could cause damage to both the generator set and the generator set clamp, and cause serious
injury during transport.

Reviews

There are no reviews yet.

Be the first to review “Buy Carrier Clip On Genset 69RG15 Online”

Your email address will not be published. Required fields are marked *